Xreferat.com » Рефераты по менеджменту » The manager as a teacher: selected aspects of stimulation of scientsfsc thinking
The manager as a teacher: selected aspects of stimulation of scientsfsc thinking
called negative.
And as the information moves back from the outlet of system towards
its beginning, it is called feedback/back action.
As a result the negative
feedback (NF) occurs. A “Y” receptor and reciprocate path
comprise NF and together with the analyzer-informant and efferent
cannels (stimulator) form a NF loop. Depending on the need and based
on the NF information the control block would engage or disengage the
functions of
controllable SFU as necessary. The difference of this system from the
composite SFU lies only in the presence of a “Y” receptor
which measures the result of action and reciprocal paths through
which the information is transferred from this receptor to the
analyzer. The number of active SFU is determined by NF. The NF is
realized by means of NF loop which includes the “Y”
receptor, reciprocal path, through which information from “Y”
receptor is transferred to the analyzer-informant, analyzer proper
and efferent channels through which the control block decisions are
transferred to the effectors (controllable SFU). Thus, the system,
unlike SFU, contains both DPC and NF. Direct positive (controllable)
communication activates the system, while negative feedback
determines the number
of activated SFU. For example,
if larger number of alveolar capillaries in lungs will be opened
compared to the number of the alveoli with appropriate gas
composition, arterialization of venous blood will be incomplete, and
there will be a need to close a part of alveolar capillaries which
“wash” by bloodstream the alveoli with gas composition
not suitable for gas exchange. If the number of such opened
capillaries will be smaller, overloading of pulmonary blood
circulation would occur and the pressure in pulmonary artery will
increase and there will be a need to open part of alveolar
capillaries. In any case the informant of pulmonary blood circulation
would snap into action and the control block would decide what part
of capillaries needs to be opened or closed. Hence, the diffusion
part of vascular channel of pulmonary bloodstream is the system
containing simple
control block. The goal of the system is that the result of action of
“Y” should be equal to the command “M” (Y=M).
Actions of system aimed at the achievement of goal are implemented by
executive elements. Control block would watch the accuracy of
implementation of actions. The control block containing DPC and NF
loop is simple. The algorithm of simple control blocks operation is
not complex. The NF loop would trace continually the result of
performance of executive elements (SFU). If the result of action
turns out to be of a larger scale than the preset result, it needs to
be reduced, and if the result is of a smaller scale than the preset
one it needs to be increased. Control parameters (the “database”)
are set through the command; for example, what should be the
correlation between external influence and the result of action, or
what level of the result of action will need to be retained, etc. At
that, the maximum accuracy would be the result of action
of one SFU (quantum of
action). Systems with NF, as well as composite SFU, also
contain two types of
objects: executive elements (SFU) (effectors which carry out specific
actions for the achievement of the preset overall
goal of the system) and
the control block (DPC and NF loop). But besides the “Х”
informant, control block of the system also contains the “Y”
informant (NF). Therefore, it has information both on the external
influence and the result of action. Some complexification of the
control block brings about a very essential result. The reason for
such a complexification is the need to achieve optimally accurate
implementation of the goal of the system. The NF ensures the
possibility of regulation of quantity of the result of action, i.e.
the system with NF may perform any required action in an optimal way,
from minimum to maximum, accurate to one quantum of action. Generally
speaking, any real system at that has the third type of objects:
service elements, i.e. substructure elements without which executive
elements cannot operate. For example, the aircraft has wings to fly,
but it also has wheels to take off and land. The haemoglobin
molecule contains haem which contains 4 SFU (ligands) and globin, the
protein which does not participate directly in transportation of
oxygen but without which haem cannot work. We have slightly touched
upon the issue of existence of the third type of objects (service
elements) for one purpose only to know that they are always present
in any system, but we
will not go into detail of their function. We will only note that
they represent the same ordinary systems aimed at serving other
systems. Systems with NF can solve most of the tasks in a far better
manner than simple or composite SFU. The presence of NF almost does
not complexicate the system. We have seen that even simple SFU is a
very complex formation including a set of components. Composite SFU
is as many times more complex compared to simple SFU as is the number
almost equal to
that of simple SFU. The system with NF is only supplemented by one
receptor and the communication link between receptor and analyzer
(reciprocal path). But the effect of such change in the structure of
control block is very large-scale and only depends on the algorithm
of the control block operation. Any SFU (simple and composite) can
implement only minimum or maximum action. Systems with NF can surely
deliver the optimal result of action, from minimum to maximum; they
are accurate and stable. Their accuracy depends only on the value of
quantum of action of separate SFU and the NF profundity/intensity/
(see below). Stability is stipulated by that the system always “sees”
the result of action and can compare it with the appropriate/due one
and correct it if divergence occurs. In real systems the causes for
the divergence are always present, since they exist in the real world
where there always exists perturbation action/disturbing influences.
Hence, one can see that it is NF that turns
SFU into real systems. How
does the control block manage the system? What parameters are
characteristic of it? Any control block is characterized by three DPC
parameters and the same number of NF loop parameters. For DPC it is a
minimal level of controllable input stimulus (threshold of
sensitivity); maximal level
of controllable input
stimulus (range of input stimulus sensitivity); time
of engagement of control
(decision-making time).
For NF loop it is minimal level of controllable result of action
(threshold of sensitivity of NF loop – NF
profundity/intensity); maximal level of controllable result of action
(range of sensitivity of the result of action); time
of engagement of control
(decision-making time).
Minimal level of controllable input signal for DPC is the sensitivity
threshold of signal of the “Х” receptor wherefrom
the analyzer-informant recognizes that the external influence has
already begun. For example, if рО2 has reached 60 mm Hg
the sphincter should be opened (1 SFU is actuated), if the рО2
value is smaller, then it is closed. Any values of рО2
smaller than 60 mm Hg would not lead to the opening of sphincter,
because these are sub-threshold values. Consequently, 60 mm Hg is the
operational threshold of sphincter. Maximum level of controllable
entrance signal (range) for DPC is the level of signal about external
influence at which all SFU are actuated. The system cannot react to
the further increase in the input signal by the extension of its
function, as it does not have any more of SFU reserves. For example,
if рО2 has reached 100 mm Hg all sphincters should be
opened (all SFU are activated). Any values of рО2 larger
than 100 mm Hg will not lead to the opening of additional sphincters,
because all of them are already opened, i.e. the values of 60-100 mm
Hg are the range of activation
of the system of
sphincters. Time of DPC activation is a time interval between the
onset of external influence and the beginning of the system’s
operation. The system would never respond immediately after the onset
of external influence. Receptors need to feel a signal, the
analyzer-informant needs to make the decision, the effectors transfer
the guiding impact to the command entry points of the executive
elements - all this takes time. The minimal level of the controllable
exit signal for NF is a threshold of sensitivity of a signal of the
“Y” receptor, wherefrom the analyzer-informant recognizes
whether there is a discrepancy between the result of action of the
system and its due value. The discrepancy should be equal to or more
than the quantum of action of single SFU. For example, if one
sphincter is to be opened and the bloodstream should be minimal (one
quantum of action), whereas two sphincters are actually opened and
the bloodstream is twice as intensive (two quanta of action), the “Y”
receptor should feel an extra quantum. If it is able of doing so, its
sensitivity is equal to one quantum. Sensitivity
is defined by the NF
profundity/intensity. The NF profundity/intensity is a number of
quanta of action of the single SFU system which sum is identified as
the discrepancy between the actual and appropriate/proper action. The
NF profundity/intensity is preset
by the command. The
highest possible NF profundity/intensity is the sensitivity of
discrepancy in one quantum of action of single SFU. The less the NF
profundity/intensity, the less is sensitivity, the more it is
“rough”. In other words, the less the NF
profundity/intensity, the larger value of the discrepancy between the
result of action and the proper result is interpreted as discrepancy.
For example, even two (three, ten, etc.) quanta of action of two
(three, ten, etc.) SFU is interpreted as discrepancy. Minimal NF
profundity/intensity is its absence. In this case any discrepancy of
the result of action with the proper one is not interpreted by the
control block as discrepancy. The result of action would be maximal
and the system with simple control block with zero NF
profundity/intensity would turn into composite SFU with DPC (with
simplest/elementary control block). For example, the system of the
Big Circle of Blood circulation
for microcirculation in fabric capillaries should hold average
pressure of 100 mm Hg accurate to 1 mm Hg. At the same time, average
arterial pressure can fluctuate from 80 to 200 mm Hg. The value “100
mm Hg” determines the level of controllable result of action.
The value “from 80 to 200 mm Hg” is the range of
controllable external (entry) influence. The value of “1 mm Hg”
is determined by NF profundity/intensity. Smaller NF
profundity/intensity would control the parameter with smaller degree
of accuracy, for example, to within 10 mm Hg (more roughly) or 50 mm
Hg (even more roughly), while the higher NF profundity/intensity
would do it with higher degree of accuracy, for example to within 0.1
mm Hg (finer). Maximal NF sensitivity is limited to the value of
quantum of action of SFU which are part of the system, and the NF
profundity/intensity. But in any case, if discrepancy between the
level of the controllable and preset parameters occurs to the extent
higher than the value of the preset accuracy, the NF loop should
“feel” this divergence and “force” executive
elements to perform so that to eliminate the discrepancy of the goal
and the result of action. Maximal level of controllable outlet/exit
signal (range) for NF is the level of signal about the result of
action of the system at which all SFU are actuated. The system cannot
react to the further increase in entry signal by increase in its
function any more, because
it has no more of SFU reserves. The time of actuating of NF control
is the time interval between the onset of discrepancy of signal about
the result of action with the preset result and the beginning of the
system’s operation. All these parameters can be “built
in” DPC and NF loops or set primordially (the command
is entered at their
“birth” and they do not further vary any more), or can be
entered through the command
later, and these
parameters can be changed by means of input of a new command from the
outside. For this purpose there should be a channel of input of the
command. Simple control block in itself cannot change
any of these parameters.
Absolutely all systems have control block, but it cannot be always
found explicitly. In the aircraft or a spaceship this block is
presented by the on-board computer, a box with electronics. In human
beings and animals such block is the brain, or at least nervous
system. But where is the control block located in a plant or
bacterium? Where is the control block located in atom or molecule,
or, for example,
the control block in a nail? The easier the system, the more
difficult it is for us to single out forms of control block habitual
for us. However, it is present in any systems. Executive elements are
responsible for the quality of result of action, while the control
block – for its quantity. The control block can be, for
example, intra- or internuclear and intermolecular connections/bonds.
For example, in atom the SFU functions are performed by electrons,
protons and neutrons, and those of control block by intra-nuclear
forces or, in other words, interactions. The intra-atomic
Если Вам нужна помощь с академической работой (курсовая, контрольная, диплом, реферат и т.д.),
обратитесь к нашим специалистам. Более 90000 специалистов готовы Вам помочь.
Бесплатные корректировки и доработки. Бесплатная оценка стоимости работы.
Нужна помощь в написании работы?
Мы - биржа профессиональных авторов (преподавателей и доцентов вузов). Пишем статьи РИНЦ, ВАК, Scopus.
Помогаем в публикации. Правки вносим бесплатно.