Xreferat.com » Рефераты по менеджменту » The manager as a teacher: selected aspects of stimulation of scientsfsc thinking

The manager as a teacher: selected aspects of stimulation of scientsfsc thinking

called negative. And as the information moves back from the outlet of system towards its beginning, it is called feedback/back action. As a result the negative feedback (NF) occurs. A “Y” receptor and reciprocate path comprise NF and together with the analyzer-informant and efferent cannels (stimulator) form a NF loop. Depending on the need and based on the NF information the control block would engage or disengage the functions of controllable SFU as necessary. The difference of this system from the composite SFU lies only in the presence of a “Y” receptor which measures the result of action and reciprocal paths through which the information is transferred from this receptor to the analyzer. The number of active SFU is determined by NF. The NF is realized by means of NF loop which includes the “Y” receptor, reciprocal path, through which information from “Y” receptor is transferred to the analyzer-informant, analyzer proper and efferent channels through which the control block decisions are transferred to the effectors (controllable SFU). Thus, the system, unlike SFU, contains both DPC and NF. Direct positive (controllable) communication activates the system, while negative feedback determines the number of activated SFU. For example, if larger number of alveolar capillaries in lungs will be opened compared to the number of the alveoli with appropriate gas composition, arterialization of venous blood will be incomplete, and there will be a need to close a part of alveolar capillaries which “wash” by bloodstream the alveoli with gas composition not suitable for gas exchange. If the number of such opened capillaries will be smaller, overloading of pulmonary blood circulation would occur and the pressure in pulmonary artery will increase and there will be a need to open part of alveolar capillaries. In any case the informant of pulmonary blood circulation would snap into action and the control block would decide what part of capillaries needs to be opened or closed. Hence, the diffusion part of vascular channel of pulmonary bloodstream is the system containing simple control block. The goal of the system is that the result of action of “Y” should be equal to the command “M” (Y=M). Actions of system aimed at the achievement of goal are implemented by executive elements. Control block would watch the accuracy of implementation of actions. The control block containing DPC and NF loop is simple. The algorithm of simple control blocks operation is not complex. The NF loop would trace continually the result of performance of executive elements (SFU). If the result of action turns out to be of a larger scale than the preset result, it needs to be reduced, and if the result is of a smaller scale than the preset one it needs to be increased. Control parameters (the “database”) are set through the command; for example, what should be the correlation between external influence and the result of action, or what level of the result of action will need to be retained, etc. At that, the maximum accuracy would be the result of action of one SFU (quantum of action). Systems with NF, as well as composite SFU, also contain two types of objects: executive elements (SFU) (effectors which carry out specific actions for the achievement of the preset overall goal of the system) and the control block (DPC and NF loop). But besides the “Х” informant, control block of the system also contains the “Y” informant (NF). Therefore, it has information both on the external influence and the result of action. Some complexification of the control block brings about a very essential result. The reason for such a complexification is the need to achieve optimally accurate implementation of the goal of the system. The NF ensures the possibility of regulation of quantity of the result of action, i.e. the system with NF may perform any required action in an optimal way, from minimum to maximum, accurate to one quantum of action. Generally speaking, any real system at that has the third type of objects: service elements, i.e. substructure elements without which executive elements cannot operate. For example, the aircraft has wings to fly, but it also has wheels to take off and land. The haemoglobin molecule contains haem which contains 4 SFU (ligands) and globin, the protein which does not participate directly in transportation of oxygen but without which haem cannot work. We have slightly touched upon the issue of existence of the third type of objects (service elements) for one purpose only to know that they are always present in any system, but we will not go into detail of their function. We will only note that they represent the same ordinary systems aimed at serving other systems. Systems with NF can solve most of the tasks in a far better manner than simple or composite SFU. The presence of NF almost does not complexicate the system. We have seen that even simple SFU is a very complex formation including a set of components. Composite SFU is as many times more complex compared to simple SFU as is the number almost equal to that of simple SFU. The system with NF is only supplemented by one receptor and the communication link between receptor and analyzer (reciprocal path). But the effect of such change in the structure of control block is very large-scale and only depends on the algorithm of the control block operation. Any SFU (simple and composite) can implement only minimum or maximum action. Systems with NF can surely deliver the optimal result of action, from minimum to maximum; they are accurate and stable. Their accuracy depends only on the value of quantum of action of separate SFU and the NF profundity/intensity/ (see below). Stability is stipulated by that the system always “sees” the result of action and can compare it with the appropriate/due one and correct it if divergence occurs. In real systems the causes for the divergence are always present, since they exist in the real world where there always exists perturbation action/disturbing influences. Hence, one can see that it is NF that turns SFU into real systems. How does the control block manage the system? What parameters are characteristic of it? Any control block is characterized by three DPC parameters and the same number of NF loop parameters. For DPC it is a minimal level of controllable input stimulus (threshold of sensitivity); maximal level of controllable input stimulus (range of input stimulus sensitivity); time of engagement of control (decision-making time). For NF loop it is minimal level of controllable result of action (threshold of sensitivity of NF loop – NF profundity/intensity); maximal level of controllable result of action (range of sensitivity of the result of action); time of engagement of control (decision-making time). Minimal level of controllable input signal for DPC is the sensitivity threshold of signal of the “Х” receptor wherefrom the analyzer-informant recognizes that the external influence has already begun. For example, if рО2 has reached 60 mm Hg the sphincter should be opened (1 SFU is actuated), if the рО2 value is smaller, then it is closed. Any values of рО2 smaller than 60 mm Hg would not lead to the opening of sphincter, because these are sub-threshold values. Consequently, 60 mm Hg is the operational threshold of sphincter. Maximum level of controllable entrance signal (range) for DPC is the level of signal about external influence at which all SFU are actuated. The system cannot react to the further increase in the input signal by the extension of its function, as it does not have any more of SFU reserves. For example, if рО2 has reached 100 mm Hg all sphincters should be opened (all SFU are activated). Any values of рО2 larger than 100 mm Hg will not lead to the opening of additional sphincters, because all of them are already opened, i.e. the values of 60-100 mm Hg are the range of activation of the system of sphincters. Time of DPC activation is a time interval between the onset of external influence and the beginning of the system’s operation. The system would never respond immediately after the onset of external influence. Receptors need to feel a signal, the analyzer-informant needs to make the decision, the effectors transfer the guiding impact to the command entry points of the executive elements - all this takes time. The minimal level of the controllable exit signal for NF is a threshold of sensitivity of a signal of the “Y” receptor, wherefrom the analyzer-informant recognizes whether there is a discrepancy between the result of action of the system and its due value. The discrepancy should be equal to or more than the quantum of action of single SFU. For example, if one sphincter is to be opened and the bloodstream should be minimal (one quantum of action), whereas two sphincters are actually opened and the bloodstream is twice as intensive (two quanta of action), the “Y” receptor should feel an extra quantum. If it is able of doing so, its sensitivity is equal to one quantum. Sensitivity is defined by the NF profundity/intensity. The NF profundity/intensity is a number of quanta of action of the single SFU system which sum is identified as the discrepancy between the actual and appropriate/proper action. The NF profundity/intensity is preset by the command. The highest possible NF profundity/intensity is the sensitivity of discrepancy in one quantum of action of single SFU. The less the NF profundity/intensity, the less is sensitivity, the more it is “rough”. In other words, the less the NF profundity/intensity, the larger value of the discrepancy between the result of action and the proper result is interpreted as discrepancy. For example, even two (three, ten, etc.) quanta of action of two (three, ten, etc.) SFU is interpreted as discrepancy. Minimal NF profundity/intensity is its absence. In this case any discrepancy of the result of action with the proper one is not interpreted by the control block as discrepancy. The result of action would be maximal and the system with simple control block with zero NF profundity/intensity would turn into composite SFU with DPC (with simplest/elementary control block). For example, the system of the Big Circle of Blood circulation for microcirculation in fabric capillaries should hold average pressure of 100 mm Hg accurate to 1 mm Hg. At the same time, average arterial pressure can fluctuate from 80 to 200 mm Hg. The value “100 mm Hg” determines the level of controllable result of action. The value “from 80 to 200 mm Hg” is the range of controllable external (entry) influence. The value of “1 mm Hg” is determined by NF profundity/intensity. Smaller NF profundity/intensity would control the parameter with smaller degree of accuracy, for example, to within 10 mm Hg (more roughly) or 50 mm Hg (even more roughly), while the higher NF profundity/intensity would do it with higher degree of accuracy, for example to within 0.1 mm Hg (finer). Maximal NF sensitivity is limited to the value of quantum of action of SFU which are part of the system, and the NF profundity/intensity. But in any case, if discrepancy between the level of the controllable and preset parameters occurs to the extent higher than the value of the preset accuracy, the NF loop should “feel” this divergence and “force” executive elements to perform so that to eliminate the discrepancy of the goal and the result of action. Maximal level of controllable outlet/exit signal (range) for NF is the level of signal about the result of action of the system at which all SFU are actuated. The system cannot react to the further increase in entry signal by increase in its function any more, because it has no more of SFU reserves. The time of actuating of NF control is the time interval between the onset of discrepancy of signal about the result of action with the preset result and the beginning of the system’s operation. All these parameters can be “built in” DPC and NF loops or set primordially (the command is entered at their “birth” and they do not further vary any more), or can be entered through the command later, and these parameters can be changed by means of input of a new command from the outside. For this purpose there should be a channel of input of the command. Simple control block in itself cannot change any of these parameters. Absolutely all systems have control block, but it cannot be always found explicitly. In the aircraft or a spaceship this block is presented by the on-board computer, a box with electronics. In human beings and animals such block is the brain, or at least nervous system. But where is the control block located in a plant or bacterium? Where is the control block located in atom or molecule, or, for example, the control block in a nail? The easier the system, the more difficult it is for us to single out forms of control block habitual for us. However, it is present in any systems. Executive elements are responsible for the quality of result of action, while the control block – for its quantity. The control block can be, for example, intra- or internuclear and intermolecular connections/bonds. For example, in atom the SFU functions are performed by electrons, protons and neutrons, and those of control block by intra-nuclear forces or, in other words, interactions. The intra-atomic
Если Вам нужна помощь с академической работой (курсовая, контрольная, диплом, реферат и т.д.), обратитесь к нашим специалистам. Более 90000 специалистов готовы Вам помочь.
Бесплатные корректировки и доработки. Бесплатная оценка стоимости работы.

Поможем написать работу на аналогичную тему

Получить выполненную работу или консультацию специалиста по вашему учебному проекту
Нужна помощь в написании работы?
Мы - биржа профессиональных авторов (преподавателей и доцентов вузов). Пишем статьи РИНЦ, ВАК, Scopus. Помогаем в публикации. Правки вносим бесплатно.

Похожие рефераты: